Einstein (Säo Paulo) ; 12(3): 330-335, Jul-Sep/2014. tab
Article in English | LILACS | ID: lil-723933

ABSTRACT

Objective To determine and to analyze the theoretical and practical knowledge of Nursing professionals on indirect blood pressure measurement. Methods This cross-sectional study included 31 professionals of a coronary care unit (86% of the Nursing staff in the unit). Of these, 38.7% of professionals were nurses and 61.3% nurse technicians. A validated questionnaire was used to theoretical evaluation and for practice assessment the auscultatory technique was applied in a simulation environment, under a non-participant observation. Results To the theoretical knowledge of the stages of preparation of patient and environment, 12.9% mentioned 5-minute of rest, 48.4% checked calibration, and 29.0% chose adequate cuff width. A total of 64.5% of professionals avoided rounding values, and 22.6% mentioned the 6-month deadline period for the equipment calibration. On average, in practice assessment, 65% of the steps were followed. Lacks in knowledge were primary concerning lack of checking the device calibration and stethoscope, measurement of arm circumference to choose the cuff size, and the record of arm used in blood pressure measurement. Conclusion Knowledge was poor and had disparities between theory and practice with evidence of steps taken without proper awareness and lack of consideration of important knowledge during implementation of blood pressure measurement. Educational and operational interventions should be applied systematically with institutional involvement to ensure safe care with reliable values. .


Objetivo Determinar e analisar o conhecimento teórico e prático de profissionais de Enfermagem sobre a medida indireta da pressão arterial. Métodos Estudo descritivo, transversal, com profissionais de Enfermagem de uma unidade coronariana. Participaram do estudo 31 sujeitos (86% da população), sendo 38,7% enfermeiros e 61,3% técnicos em enfermagem. A avaliação teórica ocorreu por meio de questionário validado, e a prática, com técnica auscultatória, em simulação, sob observação não participativa. Resultados Sobre o conhecimento teórico do preparo do cliente e ambiente, 12,9% citaram repouso de 5 minutos, 48,4% conferiram calibração e 29,0% escolheram o manguito correto. Já 64,5% evitaram o arredondamento dos valores, e 22,6% citaram o prazo semestral para a calibração dos aparelhos. Na avaliação prática, em média, 65% das etapas foram cumpridas. Dentre as lacunas desse conhecimento, destacaram-se a ausência de checagem da calibração do aparelho e do estetoscópio, a medida da circunferência braquial para escolher o manguito, e o registro do braço usado na medida. Conclusão: O conhecimento foi insatisfatório, com discrepâncias entre a teoria e a prática, com indícios de etapas cumpridas sem a devida consciência, e conhecimentos importantes negligenciados na execução da medida da pressão arterial. Intervenções educativas e operacionais devem ser sistematicamente aplicadas, com o envolvimento institucional, para garantir segurança da assistência com valores fidedignos. .


Subject(s)
Adult , Female , Humans , Male , Blood Pressure Determination/nursing , Coronary Care Units , Clinical Competence/standards , Health Knowledge, Attitudes, Practice , Nursing Staff, Hospital/standards , Brazil , Blood Pressure Determination/standards , Cross-Sectional Studies , Clinical Competence/statistics & numerical data , Nursing Assistants/standards , Nursing Assistants/statistics & numerical data , Nursing Staff, Hospital/statistics & numerical data , Surveys and Questionnaires , Time Factors
2.
Rev. saúde pública ; 47(supl.2): 113-121, jun. 2013. tab, graf
Article in Portuguese | LILACS | ID: lil-688068

ABSTRACT

OBJETIVO: Determinar a reprodutibilidade da pressão arterial casual de participantes do Estudo Longitudinal de Saúde do Adulto (ELSA-Brasil) e confirmar o diagnóstico pressórico pela monitorização. MÉTODOS: A pressão arterial casual foi medida em aparelho oscilométrico. Uma subamostra dos participantes do estado do Espírito Santo (N = 255) foi reavaliada com igual metodologia de uma a dez semanas após; além disso, foi realizada monitorização. O diagnóstico de hipertensão seguiu os pontos de corte de 140/90 mmHg ou 130/80 mmHg para a pressão casual e na monitorização, respectivamente. A hipertensão do jaleco branco foi definida pela presença hipertensão na medida casual e normotensão na monitorização e o inverso para a hipertensão mascarada. RESULTADOS: Os dados referem-se a 230 participantes que nas duas ocasiões estavam sem medicação (N1 = 153) ou sob a mesma medicação anti-hipertensiva (N2 = 77). No N1, a normotensão casual foi confirmada em 120 dos 134 pela monitorização. No N2, a monitorização confirmou o controle pressórico em 43 dos 54 participantes com pressão controlada pela medida casual. A concordância geral de diagnósticos entre a pressão casual e monitorada foi de 78% (kappa = 0,44). No grupo N1, seis indivíduos (4%) apresentaram hipertensão do jaleco branco e 23 (25%), mascarada. CONCLUSÕES: A concordância de diagnósticos entre a pressão arterial casual e a monitorada foi moderada. A padronização rigorosa da medida casual adotada no ELSA-Brasil foi capaz de reduzir a hipertensão do jaleco branco. A alta frequência de hipertensão mascarada sugere que a medida pressórica da monitorização ...


OBJECTIVE: To determine the reproducibility of casual arterial pressure measurement and to confirm pressure diagnosis by monitoring of participants in the ELSA-Brasil (Estudo Longitudinal de Saúde do Adulto - Brazilian Longitudinal Study for Adult Health). METHODS: Casual blood pressure was measured with an oscilometric device. A sub-sample of participants (N = 255) from Espírito Santo state (Southeastern Brazil) was reevaluated using the same methodology following one to ten weeks and, in addition, underwent arterial blood pressure monitoring. Diagnosis of hypertension used cut off points of 140/90 mmHg for casual pressure and 130/80 mmHg for arterial blood pressure monitoring. White coat hypertension was defined as the presence of hypertension in casual blood pressure and normal arterial blood pressure monitoring, and converse findings characterized masked hypertension. RESULTS: Data are from 230 participants that on the two occasions were free from antihypertensive medication (N1 = 153) or under the same antihypertensive regimen (N2 = 77). Normotension was confirmed by arterial blood pressure monitoring in120 out of 134 participants of the N1 group. In N2, blood pressure control was confirmed by arterial blood pressure monitoring in 43 of 54 participants with controlled hypertension per casual blood pressure. Overall diagnostic concordance between casual blood pressure and arterial blood pressure monitoring was 78% (kappa = 0.44). In the N1 group, six subjects (4%) presented white coat hypertension, and 23 subjects (25%) presented with masked hypertension. CONCLUSIONS: Diagnostic concordance between casual blood pressure and arterial blood pressure monitoring was moderate. The rigorous standardization of casual blood pressure measurement adopted in the ELSA-Brasil study was able to reduce white coat hypertension. The high frequency of masked hypertension ...


Subject(s)
Adult , Female , Humans , Male , Middle Aged , Blood Pressure Determination/methods , Hypertension/diagnosis , Blood Pressure Determination/standards , Brazil , Longitudinal Studies , Reproducibility of Results
3.
São Paulo; s.n; 2008. [78] p. tab, graf.
Thesis in Portuguese | LILACS | ID: lil-586853

ABSTRACT

INTRODUÇÃO: Não se sabe se o ajuste da terapia anti-hipertensiva baseado na Monitorização Residencial da Pressão Arterial (MRPA) pode melhorar o controle da pressão arterial em pacientes em hemodiálise. OBJETIVOS: Comparar a redução da pressão arterial (PA) e do índice de massa ventricular esquerda (IMVE) obtido com o uso da MRPA em relação às medidas da PA pré-diálise em pacientes em hemodiálise. MÉTODOS: Pacientes hipertensos em hemodiálise foram randomizados para ter a terapia anti-hipertensiva ajustada em dois grupos: controle, baseado na PA pré-diálise, e intervenção, baseada na MRPA. Antes e após 06 meses de acompanhamento, os pacientes realizaram Monitorização Ambulatorial da Pressão Arterial (MAPA) por 24 horas, MRPA durante uma semana e ecocardiograma transtorácico. RESULTADOS: 34 e 31 pacientes completaram o estudo no grupo intervenção e controle, respectivamente. As pressões arteriais sistólica (PAS) e diastólica (PAD) no período interdialítico pela MAPA foram significativamente menores no grupo intervenção em relação ao grupo controle no final do estudo (média 24 horas: 135 ± 13mmHg / 76 ± 7mmHg versus 147 ± 15mmHg / 79 ± 8mmHg, respectivamente - p<0,05). Na análise da MRPA, o grupo intervenção apresentou redução significativa somente para a PAS em comparação ao grupo controle (média semanal: 144 ± 21mmHg versus 154 ± 22 mmHg, respectivamente - p<0,05). Não houve diferenças entre os grupos intervenção e controle em relação ao IMVE ao final do estudo (108 ± 35 g/m2 versus 110 ±33 g/m2, respectivamente - p>0,05). CONCLUSÕES: O uso sistemático da MRPA no ajuste da terapia anti-hipertensiva em pacientes em hemodiálise propiciou maior controle da PA no período interdialítico em comparação às medidas da PA pré-diálise. A MRPA pode ser usada como um instrumento adjuvante útil no controle da pressão arterial em pacientes em hemodiálise.


INTRODUCTION: It is not known whether the adjustment of the antihypertensive therapy based on Home Blood Pressure Monitoring (HBPM) can improve blood pressure (BP) control in hemodialysis patients. OBJECTIVES: To compare the reduction in BP and in the left ventricular mass index (LVMI) obtained with the use of HBPM in relation to that achieved with predialysis BP measurements in hemodialysis patients. METHODS: Hypertensive patients on hemodialysis were randomized to have the antihypertensive therapy adjusted according two groups: control, based on the predialysis BP measurements, and intervention, based on HBPM. Before and after 06 months of follow-up, patients were submitted to Ambulatory Blood Pressure Monitoring (ABPM) for 24 hours, HBPM during one week and transthoracic echocardiogram. RESULTS: 34 and 31 patients completed the study in the intervention and control groups, respectively. The systolic (SBP) and diastolic (DBP) blood pressure in the interdialytic period by ABPM were significantly lower in the intervention group compared with the control group at the end of the study (mean 24-hours BP: 135 ± 13 mm Hg / 76 ± 7 mmHg versus 147 ± 15 mm Hg / 79 ± 8 mmHg, respectively - p <0.05). When the interdialytic BP was analysed by HBPM, the intervention group showed significant reduction only for the PAS in comparison with control group (mean weekly BP: 144 ± 21 mm Hg versus 154 ± 22 mm Hg, respectively - p <0.05). There were no differences between intervention and control groups in relation to LVMI at the end of the study (108 ± 36 g/m2 versus 110 ± 33 g/m2, respectively - p> 0.05). CONCLUSIONS: The systematic use of HBPM in the adjustment of antihypertensive therapy in patients on hemodialysis has led to better control of BP during interdialytic period compared to that achieved with the predialysis BP measurements. The HBPM can be used as a useful adjunct instrument to control blood pressure in hemodialysis patients.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Blood Pressure Monitoring, Ambulatory , Blood Pressure Determination/methods , Hypertension/therapy , Renal Dialysis